IEC 60601-1 4th Edition: Critical 2025 Updates for Indian Medical Device Manufacturers

IEC 60601-1 4th Edition India

Indian medical device manufacturers are entering a pivotal regulatory transition as BIS formally adopts IEC 60601-1:2020 under IS 13450:2024. This updated 4th Edition introduces a significant shift in how safety, electromagnetic compatibility (EMC), risk, and software are handled, particularly for devices regulated under CDSCO.

For manufacturers of patient monitors, ventilators, defibrillators, and other Class B, C, and D equipment, adapting to these changes is essential to avoid delays and revalidation.

Comparing IEC 60601-1 Editions: What’s Changed?

Feature

3rd Edition

4th Edition (IS 13450:2024)

Device Classification

Life-support / Non-life-support

Use-environment based

ESD Testing

8 kV air / 6 kV contact

15 kV air / 8 kV contact

Essential Performance

Loosely defined

Clinically risk-linked definition

Port-Specific Testing

Not mandatory

Required for all interfaces

Software Validation

Basic PEMS controls

AI/ML lifecycle, cybersecurity, GMLP included

Documentation

Test reports, IFU

Full technical file, EMC plan, risk traceability

Risk-Linked EMC Planning and Test Execution

Compliance now starts with a robust Risk Management File (RMF) following ISO 14971. Every EMC test must be justified based on risk, and each test result must map to a specific hazard and mitigation. Essential performance functions must be clearly identified and clinically assessed.

Testing is no longer limited to general system behavior. Each interface, from USB ports to wireless modules, must demonstrate immunity according to its intended environment.

Our medical device testing services are aligned with this new standard, offering structured test plans and RMF integration to meet BIS and CDSCO expectations.

Human Factors, Software Risk, and Cybersecurity

The 4th Edition expands expectations around software safety, user interface design, and cybersecurity. Devices with programmable electrical medical systems (PEMS), particularly those incorporating AI/ML, must comply with Good Machine Learning Practices (GMLP), implement predetermined change control plans (PCCPs), and complete IEC 81001-5-1 cybersecurity assessments.

Human factors engineering is now part of formal usability risk assessments, requiring updates to alarm systems, labeling, and control interfaces. Learn how this applies to your devices in our post on electrosurgical analyzer testing.

Regulatory Timeline: 2025 Through 2032

Phase

Timeline

Key Actions

Planning and Training

2025

Risk mapping, staff training, standard updates

Design Review

2026–2027

EMC layout, firmware checks, usability testing

Formal Testing

2028–2029

NABL-accredited testing, technical file preparation

Market Transition

2029–2032

CDSCO filing using IS 13450:2024

Start with pre-compliance EMC testing to identify design issues early and reduce final testing failure risks.

Delayed Compliance Carries High Costs

Late adoption of the 4th Edition can delay CDSCO approvals by three to six months and increase costs by 20 to 30 percent due to redesign and repeat testing. Critical-care devices like infusion pumps and ventilators face stricter scrutiny. To reduce regulatory rejections, BIS and CDSCO filings should now reflect IS 13450:2024.

Why Astute Labs Leads in 4th Edition Testing

Astute Labs offers an end-to-end testing solution to 4th Edition readiness.

Build Your 4th Edition Roadmap With Confidence

Complying with the IEC 60601-1 4th Edition is no longer optional—it is a critical part of regulatory success in India. Astute Labs can help you define essential performance clinically, implement risk-based EMC test strategies, and prepare audit-ready documentation for submission to CDSCO and BIS.

Contact us today to get started on your 2025 compliance roadmap with guidance from a lab that understands the full regulatory lifecycle.

Frequently asked questions

01. Is IEC 60601-1 4th Edition required for CDSCO filing in India?

Yes. BIS has adopted it as IS 13450:2024, and new filings must align with it. CDSCO expects supporting documentation and testing accordingly. 

Common updates include increasing ESD tolerance to 15 kV, filtering on ports, improved shielding, and clearer essential performance documentation. 

Ensure your lab is NABL-accredited for IEC 60601-1:2020 and IEC 60601-1-2:2020. Astute Labs offers testing under the latest BIS-adopted versions.

Yes. Firmware affecting essential performance or introducing new clinical risks must be evaluated under PCCPs and reflected in the RMF.  
Start with a pre-compliance review, update your RMF, and validate all environment-specific EMC risks. Early planning avoids costly delays later.  

About Author

Yash Chawlani is your go-to digital marketing specialist and founder of Merlin Marketing, a performance-driven marketing agency. With over 7 years of experience, Yash has worked with some big names like Elementor, G2, and Snov, just to name a few, to boost their online presence. When he's not diving into the latest marketing trends, you'll either find him at the gym or on the football field.